Sign In | Join Free | My disqueenfrance.com |
|
Brand Name : MOVELASER
Model Number : Molas CL
Place of Origin : China
MOQ : 1 set
Price : Dollar 1W$+ (Price consultation customer service)
Payment Terms : L/C, D/A, D/P, T/T
Supply Ability : 200 set ,1 month
Delivery Time : 1-2 months
Packaging Details : Air Box
Detection distance : 200m@90% reflectivity/ 140m@10% reflectivity
Range resolution : ≤0.1m
Measurement accuracy : ±0.2m
Repeated measurement accuracy : ±0.2m
Resistance to ambient light : 100Klux
Wavelength : 905nm
Repeat frequency : 20KHz per channel
Laser safety level : Class 1
Range of working temperature : -40℃~+60℃
Survival temperature range : -45℃~+65℃
Working humidity range : 0%~100% RH
Enclosure rating : IP65 (or according to specific needs)
Working acceleration range : -0.5g ~ 0.5g
Luminous flux 1 : 0°
Luminous flux 2 : 2.05°±0.2°
Luminous flux 3 : 4.09°±0.2°
Fieldbus : Profibus DP / Modbus RTU / CANopen Three fieldbus protocols, and RS485 communication can be customized
Supply voltage and maximum current : DC 24V, 3A
Size 200×200×250mm CL Wind Lidar
1,Product introduction
MolasCL power supply is 24V DC, the maximum current is 3A. The allowable deviation of the DC power supply voltage is -15% to +10%, and the ripple coefficient of the DC power supply voltage is less than 5%. The end of the power supply cable is marked with "+24V" and "0V", and the end is connected to a tubular pre-insulated terminal.
2,Technical Data Sheet
Ranging index | |
Ranging method | 1ToF |
Detection distance | 200m@90% reflectivity/ 140m@10% reflectivity |
Range resolution | ≤0.1m |
Measurement accuracy | ±0.2m |
Repeated measurement accuracy | ±0.2m |
Resistance to ambient light | 100Klux |
Optical index | |
Wavelength | 905nm |
Repeat frequency | 20KHz per channel |
Laser safety level | Class 1 |
Environmental adaptability | |
Range of working temperature | -40℃~+60℃ |
Survival temperature range | -45℃~+65℃ |
Working humidity range | 0%~100% RH |
Enclosure rating | IP65 (or according to specific needs) |
Working acceleration range | -0.5g ~ 0.5g |
Beam pointing | |
Luminous flux 1 | 0° |
Luminous flux 2 | 2.05°±0.2° |
Luminous flux 3 | 4.09°±0.2° |
Output measurement results | |
Real-time data products | Device ID, directly measure distance, return light intensity, Data valid flag, system status |
Fieldbus | Profibus DP / Modbus RTU / CANopen Three fieldbus protocols, and RS485 communication can be customized |
Qther | |
Operating power consumption | Within 60W |
Supply voltage and maximum current | DC 24V, 3A |
Size | 200×200×250mm |
![]() |